Antlia syringetica portatilis et ad usum hospitalem ad anaesthesiam
Antlia syringetica anaesthesiae portatilis et nosocomialis,
Antlia Syringae Anaesthesiae,
Specificationes
| Modellum | KL-605T |
| Magnitudo Syringae | 5, 10, 20, 30, 50/60 millilitra |
| Syringa applicabilis | Compatibilis cum syringe cuiuslibet normae |
| VTBI | 1-1000 ml (in incrementis 0.1, 1, 10 ml) |
| Fluxus Ratio | Iniectio 5 ml: 0.1-100 ml/h (in incrementis 0.01, 0.1, 1, 10 ml/h) Iniectio 10 ml: 0.1-300 ml/h Iniectio 20 ml: 0.1-600 ml/h Iniectio 30 ml: 0.1-800 ml/h Iniectio 50/60 ml: 0.1-1200 ml/h |
| Bolus Rate | 5 ml: 0.1-100 ml/h (in incrementis 0.01, 0.1, 1, 10 ml/h) 10 ml: 0.1-300 ml/h 20 ml: 0.1-600 ml/h 30 ml: 0.1-800 ml/h 50/60 ml: 0.1-1200 ml/h |
| Anti-Bolus | Automaticus |
| Accuratio | ±2% (praecisio mechanica ≤1%) |
| Modus Infusionis | 1. Modus facilis 2. Fluxus celeritas 3. Secundum tempus 4. Pondus corporis 5. TCI plasmatica 6. Effectus TCI |
| KVO Rate | 0.1-1 ml/h (in incrementis 0.01 ml/h) |
| Alarmae | Occlusio, prope vacuum, finis programmatis, pila debilis, pila finita, Exstinctio potentiae AC, vitiatio motoris, vitiatio systematis, modus exspectationis, error sensoris pressionis, error institutionis syringe, depositio syringe |
| Proprietates Additiciae | Volumen infusum in tempore reali, commutatio potentiae automatica, identificatio automatica syringe, clavis silentii, purgatio, bolus, anti-bolus, memoria systematis, diarium historiae |
| Bibliotheca Medicamentorum | Disponibile |
| Sensibilitatem Occlusionis | Altus, medius, humilis |
| Index Historiae | Quinque milia eventuum |
| Fons Potentiae, AC | 110-230 V, 50/60 Hz, 20 VA |
| Batteria | 14.8 V, recargabilis |
| Duratio Batteriae | Octo horae ad quinque ml/h |
| Temperatura Operativa | 5-40℃ |
| Humiditas Relativa | 20-90% |
| Pressio Atmosphaerica | 700-1060 hpa |
| Magnitudo | 245*120*115 mm |
| Pondus | 2.5 chiliogrammata |
| Classificatio Salutis | Classis II, typus BF |
Modellum
KL-605T
Magnitudo iniectionis: 5, 10, 20, 30, 50/60 ml
Syringa applicabilis: Compatibilis cum syringa cuiuslibet normae
VTBI: 1-1000 ml (in incrementis 0.1, 1, 10 ml)
Fluxus Ratio
Iniectio 5 ml: 0.1-100 ml/h (in incrementis 0.01, 0.1, 1, 10 ml/h)
Iniectio 10 ml: 0.1-300 ml/h
Iniectio 20 ml: 0.1-600 ml/h
Iniectio 30 ml: 0.1-800 ml/h
Iniectio 50/60 ml: 0.1-1200 ml/h
Bolus Rate
5 ml: 0.1-100 ml/h (in incrementis 0.01, 0.1, 1, 10 ml/h)
10 ml: 0.1-300 ml/h
20 ml: 0.1-600 ml/h
30 ml: 0.1-800 ml/h
50/60 ml: 0.1-1200 ml/h
Anti-Bolus: Automaticus
Accuratio: ±2% (accuratio mechanica ≤1%)
Modus Infusionis
1. Modus facilis
2. Fluxus celeritas
3. Secundum tempus
4. Pondus corporis
5. TCI plasmatica
6. Effectus TCI
KVO Rate: 0.1-1 ml/h (in incrementis 0.01 ml/h)
Alarmae:
Occlusio, prope vacuum, finis programmatis, pila debilis, pila finita,
Exstinctio potentiae AC, vitia motoris, vitia systematis, admonitio alarmi,
error sensoris pressionis, error institutionis syringe, depositio syringe
Proprietates Additiciae:
Volumen infusum in tempore reali, commutatio potentiae automatica,
identificatio automatica syringe, clavis silentii, purgatio, bolus, anti-bolus,
memoria systematis, diarium historiae
Bibliotheca Medicamentorum: Praesto
Sensibilitatem Occlusionis: Altam, mediam, humilem
Fons Electricus, AC: 110/230 V, 50/60 Hz, 20 VA
Pila: 14.8 V, recargabilis
Duratio pilae: 8 horae ad 5 ml/h
Temperatura Operandi: 5-40℃
Humiditas Relativa: 20-90%
Pressio Atmosphaerica: 700-1060 hpa
Magnitudo: 245*120*115 mm
Pondus: 2.5 kg
Classificatio Salutis: Classis II, typus BF