| Mechanismus Pumpandi | Peristaltica curvilinea |
| Series IV | Compatibilis cum apparatibus intravenosis cuiuslibet normae |
| Fluxus Ratio | 0.1-2000 ml/h 0.10~99.99 mL/h(in incrementis 0.01 ml/h) 100.0~999.9 mL/h(incrementis 0.1 ml/h) mille~2000 mL/h(in incrementis 1 ml/h) |
| Guttae | 1 gutta/min - 100 guttae/min (in incrementis 1 guttae/min) |
| Accuratio Fluxus | ±5% |
| Accuratio Rationis Dejectionis | ±5% |
| VTBI | 0.10mL~99999.99mL(Minimum in incrementis 0.01 ml/h) |
| Accuratio Voluminis | <1 millilitrum,±0.2mL >1ml,±5 mL |
| Tempus | 00:00:01~99:59:59 (hora:m:s)(Minimum in incrementis 1s) |
| Fluxus (Pondus corporis) | 0.01~9999.99ml/h; (in incrementis 0.01 ml) unitas:ng/kg/min...ng/kg/h...ug/kg/min...ug/kg/h...mg/kg/min...mg/kg/h...IU/kg/min...UI/kg/h...EU/kg/min...EU/kg/h |
| Bolus Rate | Ambitus fluxus: 50~2000 mL/h&c.,Incrementa: (50~99.99)mL/h(Minimum in incrementis 0.01mL/h) ()100.0~999.9()mL/h(Minimum in incrementis 0.1mL/h) ()mille~MM()mL/h(Minimum in incrementis 1 mL/h) |
| Volumen Boli | 0.1-50 ml (in incrementis 0.01 ml) Accuratio:±5% vel±0.2mL |
| Bolus, Purgatio | 50~2000 mL/h(in incrementis 1 mL/h) Accuratio:±5% |
| Libella Bullae Aeris | 40~800µL,adaptabilis.(in20µLincrementa) Accuratio:±15µL or±XX% |
| Sensibilitatem Occlusionis | 20kPa-130kPa, adaptabilis (in10 kPaincrementa) Accuratio: ±15 kPa or±15% |
| KVO Rate | 1). Functio automatica KVO activanda/exactivanda 2).Automatic KVO submovetur: KVO Rate:0.1~10.0 mL/hadaptabilis&c.,(Minimum(incrementis 0.1mL/h). Cum fluxus > celeritas KVO, in celeritate KVO currit. Cum fluxus celeritas 3) KVO automaticum accenditur: fluxus ratem sponte accommodat. Cum fluxus celeritas <10mL/h, KVO celeritas = 1mL/h Cum fluxus celeritas >10 mL/h, KVO = 3 mL/h. Accuratio:±5% |
| Functio fundamentalis | Monitorium Pressionis Dynamicum, Clavium Armarium, Exspectatio, Memoria Historica, MedicamentorumLbibliotheca |
| Alarmae | Occlusio, aer in linea, ianua aperta, prope finem, finis programmatis, pila humilis, pila finita, malfunctio motoris, malfunctio systematis, error casus, alarmum subsidii |
| Modus Infusionis | Modus Frequentiae, Modus Temporis, Pondus Corporis, Modus Sequentiae, Modus Dosis, Modus Incrementi/Decrementi, Modus Micro-Infusionis, Modus Decrementi. |
| Proprietates Additiciae | Auto-probatio, Memoria Systematis, Sine Filo (libitum), Cascade, Monitum de Defectu Pilae, Monitum de Exstinctione Potentiae AC. |
| Detectio Aeris in Linea | Detector ultrasonicus |
| Fons Potentiae, AC | AC 100V~240V 50/60Hz,35 VA |
| Batteria | 14.4 V, 2200mAh, lithium, recargabilis |
| Pondus Batteriae | 210g |
| Duratio Batteriae | Decem horae ad 25 ml/h |
| Temperatura Operativa | 5Celsius~XLCelsius |
| Humiditas Relativa | 15%~80% |
| Pressio Atmosphaerica | 86KPa~106KPa |
| Magnitudo | 240×87×176mm |
| Pondus | <2.5 chiliogrammata |
| Classificatio Salutis | Classis I, typus CF. IPX3 |
Quaestiones Frequentes:
Q: Quid est MOQ (Minimum Pretium Money) pro hoc exemplo?
A: 1 unitas.
Q: Estne OEM acceptabile? et quid est MOQ (Minimum Quantum Pretii) pro OEM?
A: Ita, OEM facere possumus secundum triginta unitates.
Q: Esne tu huius producti fabricator?
A: Ita, ab anno MCMXCIV.
Q: Habesne certificata CE et ISO?
A: Ita. Omnia nostra producta certificatione CE et ISO praedita sunt.
Q: Quid est praestatio?
A: Biennium praestamus. (or: Duorum annorum praestationem damus.)
Q: Estne hoc exemplar cum statione connexa functionabile?
A: Ita