Antlia Syringae KL-6061N
Antlia Syringae KL-6061N
Specificationes
| Magnitudo Syringae | 5, 10, 20, 30, 50/60 millilitra |
| Syringa applicabilis | Compatibilis cum syringe cuiuslibet normae |
| Fluxus Ratio | Iniectio 5 ml: 0.1-100 ml/h Iniectio 10 ml: 0.1-300 ml/h Iniectio 20 ml: 0.1-600 ml/h Iniectio 30 ml: 0.1-800 ml/h Iniectio 50/60 ml: 0.1-1500 ml/h 0.1-99.99 mL/h, in incrementis 0.01 ml/h 100-999.9 ml/h in incrementis 0.1 ml/h 1000-1500 ml/h in incrementis 1 ml/h |
| Accuratio Fluxus | ±2% |
| VTBI | 0.10mL~99999.99mL(Minimum in incrementis 0.01 ml/h) |
| Accuratio | ±2% |
| Tempus | 00:00:01~99:59:59 (hora:m:s)(Minimum in incrementis 1s) |
| Fluxus (Pondus corporis) | 0.01~9999.99ml/h; (in incrementis 0.01 ml) unitas:ng/kg/min...ng/kg/h...ug/kg/min...ug/kg/h...mg/kg/min...mg/kg/h...IU/kg/min...UI/kg/h...EU/kg/min...EU/kg/h |
| Bolus Rate | Iniectio 5 ml: 50 mL/h - 100.0 mL/h Iniectio 10 ml: 50 mL/h - 300.0 mL/h Iniectio 20 ml: 50 mL/h - 600.0 mL/h Iniectio 30 ml: 50 mL/h - 800.0 mL/h Iniectio 50/60 ml: 50 mL/h-1500.0 mL/h 50-99.99 mL/h, in incrementis 0.01 ml/h 100-999.9 ml/h in incrementis 0.1 ml/h 1000-1500 ml/h in incrementis 1 ml/h Accurate: ±2% |
| Volumen Boli | Iniectio 5 ml: 0.1 mL-5.0 mL Iniectio 10 ml: 0.1 mL-10.0 mL Iniectio 20 ml: 0.1 mL-20.0 mL Iniectio 30 ml: 0.1 mL-30.0 mL Iniectio 50/60 ml: 0.1 mL-50.0 /60.0 mL Accuratio:±2% vel±0.2mL |
| Bolus, Purgatio | Syringa5mL:50mL/h-100.0 mL/h Syringa10mL:50mL/h-300.0 mL/h Syringa20mL:50 mL/h-600.0 mL/h Syringa30mL:50 mL/h-800.0 mL/h Syringa50mL:50 mL/h-1500.0 mL/h (Minimum inIncrementa 1mL/h) Accuratio:±2% |
| Sensibilitatem Occlusionis | 20kPa-130kPa, adaptabilis (in10 kPaincrementa) Accuratio: ±15 kPa or±15% |
| KVO Rate | 1). Functio automatica KVO activata/exactivata 2).Automatic KVO submovetur: KVO Rate:0.1~10.0 mL/hadaptabilis&c.,(Minimum(incrementis 0.1mL/h). Cum fluxus > celeritas KVO, in celeritate KVO currit. Cum fluxus celeritas 3) KVO automaticum accenditur: fluxus ratem sponte accommodat. Cum fluxus celeritas <10mL/h, KVO celeritas = 1mL/h Cum fluxus celeritas >10 mL/h, KVO = 3 mL/h. Accuratio:±2% |
| Functio fundamentalis | Monitorium pressionis dynamicae, Anti-Bolus, Clavium Armarium, Exspectatio, Memoria historica, Bibliotheca medicamentorum. |
| Alarmae | Occlusio, casus syringee, ianua aperta, prope finem, finis programmatis, pila humilis, pila finita, malfunctio motoris, malfunctio systematis, alarma subsidiaria, error institutionis syringee |
| Modus Infusionis | Modus Frequentiae, Modus Temporis, Pondus Corporis, Modus Sequentiae, Modus Dosis, Modus Incrementi/Decrementi, Modus Micro-Infusionis |
| Proprietates Additiciae | Auto-probatio, Memoria Systematis, Sine Filo (facultativum), Cascade, Monitum de Defectu Pilae, Monitum de Exstinctione Potentiae AC. |
| Detectio Aeris in Linea | Detector ultrasonicus |
| Fons Potentiae, AC | AC 100V~240V 50/60Hz,35 VA |
| Batteria | 14.4 V, 2200mAh, lithium, recargabilis |
| Pondus Batteriae | 210g |
| Duratio Batteriae | Decem horae ad 5 ml/h |
| Temperatura Operativa | quinqueCelsius~XLCelsius |
| Humiditas Relativa | 15%~80% |
| Pressio Atmosphaerica | 86KPa~106KPa |
| Magnitudo | 290×84×175mm |
| Pondus | <2.5 chiliogrammata |
| Classificatio Salutis | Classis I, typus CF. IPX3 |
Quaestiones Frequentes:
Q:Quod est MOQ (Minimum Pretium Money) pro hoc exemplo?
A: 1 unitas.
Q: Estne OEM acceptabile? et quid est MOQ (Minimum Quantum Pretii) pro OEM?
A: Ita, OEM facere possumus secundum triginta unitates.
Q: Esne tu huius producti fabricator?
A: Ita, ab anno MCMXCIV.
Q: Habesne certificata CE et ISO?
A: Ita. Omnia nostra producta certificatione CE et ISO praedita sunt.
Q: Quid est praestatio?
A: Biennium praestamus. (or: Duorum annorum praestationem damus.)
Q: Estne hoc exemplar cum statione connexa functionabile?
A: Ita