vexillum_capitularium

Antlia Infusionis KL-8081N

Antlia Infusionis KL-8081N

Descriptio Brevis:

1. Magna ostentus LCD

2. Lata varietas fluxus ab 0.1~2000 ml/h; (in incrementis 0.01, 0.1, 1 ml)

3. KVO Automaticum cum Functione On/Off

4. Mutare fluxus celeritatem sine antlia sistenda

5. Octo modi operandi, duodecim gradus occlusionis sensibilitatis.

6. Aptus cum statione connexa.

7. Automaticum multi-canale relais.

8. Transmissio datorum multiplicium


Detalia Producti

Etiquettae Productarum

Mechanismus Pumpandi Peristaltica curvilinea
Series IV Compatibilis cum apparatibus intravenosis cuiuslibet normae
Fluxus Ratio 0.1-2000 ml/h

0.10~99.99 mL/h (in incrementis 0.01 ml/h)

100.0~999.9 mL/h (in incrementis 0.1 ml/h)

1000~2000 mL/h (in incrementis 1 ml/h)

Guttae 1 gutta/min - 100 guttae/min (in incrementis 1 guttae/min)
Accuratio Fluxus ±5%
Accuratio Rationis Dejectionis ±5%
VTBI 0.10mL ~ 99999.99mL (Minimum in incrementis 0.01 ml/h)
Accuratio Voluminis <1 ml, ±0.2 ml

>1ml, ±5mL

Tempus 00:00:01~99:59:59(h:m:s) (Minimum in incrementis 1s)
Fluxus (Pondus corporis) 0.01~9999.99 ml/h; (in incrementis 0.01 ml)

unit: ng/kg/min、ng/kg/h、ug/kg/min、ug/kg/h、mg/kg/min、mg/kg/h、IU/kg/min、IU/kg/h、EU/kg/min、EU/kg/h

Bolus Rate Ambitus fluxus: 50~2000 mL/h, Incrementa:

(50~99.99) mL/h, (Minimum in incrementis 0.01 mL/h)

(100.0~999.9) mL/h, (Minimum in incrementis 0.1 mL/h)

(1000~2000) mL/h, (Minimum in incrementis 1 mL/h)

Volumen Boli 0.1-50 ml (in incrementis 0.01 ml)

Accuratio: ±5% vel ±0.2mL

Bolus, Purgatio 50~2000 mL/h (in incrementis 1 mL/h)

Accuratio: ±5%

Libella Bullae Aeris 40~800µL, adaptabilis (in incrementis 20µL)

Accuratio: ±15µL vel ±20%

Sensibilitatem Occlusionis 20kPa-130kPa, adaptabilis (in incrementis 10kPa)

Accuratio: ±15 kPa vel ±15%

KVO Rate 1). Functio automatica KVO activanda/exactivanda

2). KVO automatice inactivum est: KVO rate: 0.1~10.0 mL/h adaptabilis (minimum in incrementis 0.1 mL/h).

Cum fluxus > celeritas KVO, in celeritate KVO currit.

Cum fluxus celeritas

3) KVO automaticum accenditur: fluxus ratem sponte accommodat.

Cum fluxus celeritas <10mL/h, KVO celeritas = 1mL/h

Cum fluxus celeritas >10 mL/h, KVO = 3 mL/h.

Accuratio: ±5%

Functio fundamentalis Monitorium Pressionis Dynamicum, Clavium Armarium, Modus Exspectationis, Memoria historica, Bibliotheca Medicamentorum.
Alarmae Occlusio, aer in linea, ianua aperta, prope finem, finis programmatis, pila humilis, pila finita, malfunctio motoris, malfunctio systematis, error casus, alarmum subsidii
Modus Infusionis Modus Frequentiae, modus Temporis, pondus corporis, modus Sequentiae, modus Dosis, modus Accentus/Decrescens, modus Micro-Infusionis, modus Dejectionis.
Proprietates Additiciae Auto-probatio, Memoria Systematis, Sine Filo (libitum), Cascade, Monitum de Defectu Pilae, Monitum de Exstinctione Potentiae AC.
Detectio Aeris in Linea Detector ultrasonicus
Fons Potentiae, AC AC 100V ~ 240V 50/60Hz, 35VA
Batteria 14.4 V, 2200 mAh, lithium, recargabilis
Pondus Batteriae 210g
Duratio Batteriae Decem horae ad 25 ml/h
Temperatura Operativa 5℃~40℃
Humiditas Relativa 15% ~ 80%
Pressio Atmosphaerica 86KPa ~ 106KPa
Magnitudo 240×87×176mm
Pondus <2.5 chiliogrammata
Classificatio Salutis Classis I, typus CF. IPX3

  • Praecedens:
  • Deinde:

  • Nuntium tuum hic scribe et nobis mitte.